Lower Emissions

Not sure which solution fits your needs? Contact Your Rep

Overview

Cleaver-Brooks works with customers to tailor solutions that help them decrease emission levels to both be more environmentally friendly and meet ever stringent guidelines. In some cases, that means replacing the boiler system. In other cases, Cleaver-Brooks can retrofit products to help a company meet its emission goals.

Explore our product selector by using the tabs to view the options appropriate for your needs.

New Boiler

Whether you choose a Firetube or Watertube, large or small capacity, all Cleaver-Brooks boilers are designed to be as efficient as possible and provide the lowest emissions.

CBEX Elite CBND Electric Boilers ClearFire®-C
View Full Product
Details
View Full Product
Details
View Full Product
Details
View Full Product
Details
CBEX Elite

Highest Efficiency

  • Steam and hot water
  • 100 to 1,200 HP
  • Natural gas, #2 light oil or combination
  • 50 to 250+ psig on steam, 30 to 125 psig on hot water
  • Available to <5 ppm NOx
CBND

Steam Ready

  • Saturated steam
  • 10,000 to 225,000 lb/hr
  • Natural gas and #2 oil
  • 100 to 375 psig
  • Available to < 9 ppm NOx
Electric

Models: CR, HSB, IWH, S, WB

  • Electric steam boiler with condensate return
  • 12 to 3375 kW, 2 to 330 HP
  • Electrical power
  • 15 to 250 psig on steam and 160 psig on hot water
  • No localized emissions
ClearFire-C

Fully Condensing

  • Fully condensing hot water boiler
  • 500 to 2,500 MBTU
  • Natural gas and propane
  • 125 psi
  • Standard < 20 ppm NOx

Upgrade Your Burner

Every Cleaver-Brooks burner is designed and built to increase your boiler’s efficiency and decrease emissions.

ProFire®-XL Series ProFire®-D Series NATCOM Custom Burner NATCOM Retrofit Burner
View Full Product
Details
View Full Product
Details
View Full Product
Details
View Full Product
Details
ProFire-XL (Vertical)

Large, Forced Draft Burner

  • 37.8 to 92.4 MMBTU input range
  • 900 to 2,200 HP
  • Gas, oil, combination
  • Available to <9 ppm NOx
ProFire-D

Forced Draft Burner

  • 4.2 to 42.0 MMBTU input range
  • 100 to 1,000 HP
  • Gas and #2-#6 oil, combination, alt. fuels
  • Available to < 9 ppm NOx
NATCOM Custom Burner

Custom Burner Systems

  • Steam and hot water applications
  • 20 to 400 MMBTU
  • Natural gas, #2 and #6 oil, combination, other
  • Available to <9 ppm NOx, <50 ppm CO
  • Custom applications
NATCOM Retrofit Burner

Retrofit Systems

  • Steam and hot water applications
  • 20 to 400 MMBTU
  • Natural gas, #2 and #6 oil, combination, other
  • Available to <9 ppm NOx, <50 ppm CO
  • Saves fuel and lowers emissions

Controls

Ensure your system runs at peak efficiency with our integrated boiler room controls. Regardless of your boiler system, there's a control that will complement it.

Hawk 2000 Hawk 3000 Hawk 4000
View Full Product
Details
View Full Product
Details
View Full Product
Details
Hawk 2000

Complete Boiler Room Control

  • Saves fuel
  • Keeps your boiler operating at peak performance
  • 4” color touch screen
  • Intuitive interface
  • New or retrofit boiler applications
Hawk 3000

Integrated Boiler Room Control

  • Saves fuel
  • Integrated boiler control system
  • Optional oxygen trim and variable speed drive
  • Fuel-to-air ratio control
  • 7” color touch-screen Interface
  • New or retrofit boiler applications
Hawk 4000

Advanced Boiler Room Control

  • Saves fuel
  • Optional oxygen trim and variable-speed drive
  • Control economizers and other equipment
  • 10” color touch-screen interface, PLC-based
  • Custom programming available

Heat Recovery

Allow your boiler to run more efficiently and reduce fuel usage with economizers and heat exchangers.

CCE Economizer C2X Economizer Flash Tank Heat Recovery Blowdown Heat Recovery
View Full Product
Details
View Full Product
Details
View Full Product
Details
View Full Product
Details
CCE

Cylindrical Design

  • Steam and hot water applications
  • Saves fuel by preheating feedwater
  • Boilers up to 250 HP
  • Accommodates all boiler design pressures
  • Accommodates heavy oil fuel
Condensing Economizer

Condensing Economizer

  • Steam applications
  • Captures more energy than a stack economizer
  • Ideal for larger boilers
  • Boilers up to 2,200 HP
  • Accommodates all boiler design pressures
Flash Tank

Model AHR

  • For steam applications
  • Captures waste heat from blowdown process
  • Preheats cold makeup water
  • Up to 22 gpm blowdown
  • Up to 180 gpm makeup
Blowdown Heat Recovery

Capture Waste Heat

  • For steam applications
  • Captures waste heat from blowdown process
  • Maintains desired level of total dissolved solids (TDS)
  • Up to 22 gpm blowdown
  • Up to 180 gpm makeup

Water Systems

Increase the safety, reliability and life of your boiler with water treatment and feed and recovery options.

SprayMaster Signature Deaerator Surge Tank Boiler Feed System Water Softeners
View Full Product
Details
View Full Product
Details
View Full Product
Details
View Full Product
Details
SprayMaster Signature Deaerator

Model SMP

  • 7,000-100,000 Lbs/hr.
  • Steam and Hot Water applications
Surge Tank

Model SRG

  • 300-3,000 Lbs/hr.
  • Steam and Hot Water applications
BoilerFeedSystem

Model BFS

  • Atmospheric pressure
  • Steam and Hot Water applications
  • Up to 1,000 gallons
Water Softener - FMR

Models: SSE, FSE, & SMR

  • Steam and hot water applications
  • Removes hardness from feedwater
  • Prevents harmful scale
  • Tanks of FRP plastic or steel
  • For any size boiler

Parts & Service

Turnkey conversions and comprehensive upgrade and retrofit capabilities from our world-class engineering staff make it easy to lower emissions or bring any age system back to the manufacturer’s original specifications. Whatever advantage or benefit you may need, Cleaver-Brooks has the solution and dedicated aftermarket team to help you engineer and implement it.

Our proprietary BOOSTSM report can determine the exact upgrades and accessories your existing boiler system needs to increase its efficiency to its absolute maximum and decrease emissions. By installing the right burners, controls and heat recovery equipment, you can realize substantial savings immediately, and savings of hundreds of thousands of dollars over the life of the boiler. And our financial report details the cost savings in real numbers, so you can prove it’s the right thing to do.

Complete our information request form with your system’s details and a member of our Parts and Service team will help you develop a custom solution, or contact your local rep today to start developing a program that’s right for you.